Chro­ma­togra­phy
Free

The SICRIT® Ion Source al­lows ana­ly­ti­cal che­mists, R&D teams and rou­ti­ne la­bo­ra­to­ries to per­form chro­ma­to­gra­phy-free di­rect in­jec­tions with pre­cis­i­on and re­lia­bi­li­ty. The sys­tem sup­ports ful­ly quan­ti­ta­ti­ve me­a­su­re­ments th­rough de­sorp­ti­on, di­rect ana­ly­sis, jet de­sorp­ti­on, breath ana­ly­sis and VOC mo­ni­to­ring.

Line art of the SICRIT® Ion Source in com­bi­na­ti­on with the GC/SPME-mo­du­le and a syringe approaching from above as an application of Direct MS

Chro­ma­to­gra­phy-Free Di­rect In­jec­tions of Dif­fe­rent Samples

Icon in a hexagon that resembles three small hexagons and that stands for solid samples for Direct MS

So­lid samples via ther­mal de­sorp­ti­on

The SICRIT® Ion Source in com­bi­na­ti­on with the de­sorp­ti­on mo­du­le en­ables di­rect and quan­ti­ta­ti­ve ana­ly­sis of so­lid samples th­rough SPME fi­bers.

Icon in a hexagon that resembles two drops and that stands for liquid samples for Direct MS

Li­quid samples via va­po­riza­ti­on
The SICRIT® Ion Source in com­bi­na­ti­on with the de­sorp­ti­on mo­du­le en­ables di­rect and quan­ti­ta­ti­ve ana­ly­sis of li­quid samples th­rough va­po­riza­ti­on.

Icon in a hexagon that resembles a cloud and that stands for gas samples for Direct MS

Gas samples via di­rect in­jec­tion
The SICRIT® Ion Source in com­bi­na­ti­on with the de­sorp­ti­on mo­du­le en­ables di­rect and quan­ti­ta­ti­ve head­space me­a­su­re­ments of gas­eous samples.

Chro­ma­to­gra­phy-Free Di­rect MS Ana­ly­sis by „Snif­fing“

The SICRIT® Ion Source en­ables to per­form sen­si­ti­ve di­rect MS me­a­su­re­ments on any LC-MS in­stru­ment wi­t­hout sam­ple pre­pa­ra­ti­on, just by pla­cing the sam­ple in front of the source.

Chro­ma­to­gra­phy-Free Jet De­sorp­ti­on

The SICRIT® Ion Source in com­bi­na­ti­on with the Jet De­sor­ber en­ables real-time ana­ly­sis of so­lids and li­quids wi­t­hout com­plex sam­ple pre­pa­ra­ti­on by using a hot air or ni­tro­gen jet to di­rect­ly io­ni­ze even low-vo­la­ti­le com­pounds.

Line art of the SICRIT® Ion Source combined with the Breath-Mo­du­le as an application of Direct MS

Chro­ma­to­gra­phy-Free Breath Ana­ly­sis

The SICRIT® Ion Source in com­bi­na­ti­on with the Breath-Mo­du­le en­ables non-in­va­si­ve dia­gno­stics e.g., ba­sed on bio­mar­ker dis­co­very in exha­led breath.

Mo­ni­to­ring of Aro­ma and VOCs

The Ha­Voc sen­so­ry sys­tem en­ables the use of la­bo­ra­to­ry gra­de MS-Sys­tems as au­to­ma­ted VOC sen­sors in an in­dus­tri­al en­vi­ron­ment. It ser­ves the In­dus­try 4.0 de­mand of high­ly sen­si­ti­ve but easy to use real-time sen­sors.